Get started by purchasing a unit, drawing a plan, and consulting with a plumbing inspector to make sure the plumbing will meet code. Save my name, email, and website in this browser for the next time I comment. Also, dont connect the upflush vent to the vent-and-soil stack below the lowest wastewater drain connection. Close the toilet lid before flushing; leave restroom stall immediately after flushing. Venting a Saniflo Upflush toilet is a straightforward process. A macerating unit must be connected to a horizontal outlet toilet. A shower can be installed on most of our products. After that, connect and tighten the two connectors. The small size of air admittance valves makes it possible to install it just about anywhere in the home. You should have chosen this model by now. This will keep odors from coming into your living space. If access to the houses vent system isnt possible, the vent pipe can run along the beams outside the house. The entire process takes just a few seconds and is quiet and sanitary. A pump drives wastewater up a tiny pipe into the city sewage system. If I did that, all of the waste water would run down into the upflush toilet unit. "Large and comfortable, water-efficient toilet with a powerful pump and insulated tank, and a long battery life". Since the Sanicompact 48 and Sanistar versions are self-contained, they do not need a vent connection. This setup may seem complex but its actually one of the simpler ones. With the ventilation system of the upper floor in place, the entire process of venting your basement bathroom toilet becomes even easier. suggestions. Incinerating Toilet: How it Works, Pros, Cons & Types, Common Problems with Wall Mounted Toilets + Fixes, Types of Plungers for Toilet & Bathroom Sinks, Sink Plunger vs Toilet Plunger: Differences & Similarities, What is a Dual Flush Toilet, How it Works, Parts & Best Review, Types of Toilet Flush Systems, Mechanisms & the Best Designs. The discharge pipe must be set up to pump straight up vertically to the highest point and then horizontal with a slope of at least 1/4 inch per linear foot into the main drain pipe. Take a look at some of our Trade-Trusted Solutions! I w Im rewiring my house and while crawling around in the attic I could smell s How would you know if the vent is plugged ? As such, a discharge line can either be 3/4 or 1 inch in diameter while the Sanicubic range uses a 1-1/2 inch diameter discharge pipe. If this is a concern for you, insulate the pipes. Remember that plumbing codes can (and often do) vary by locality. When venting Saniflo upflush toilets, avoid using cheater vents or AAVs because they will create airlocks and cause sewer gases to waft into your house. How to install the toilet? A p-trap is required on any fixtures draining into the pump. Turn on your Saniflo system and allow it to run for a few minutes so that any air bubbles can be purged from the lines. It can handle the effluent from a toilet and sink in a residential application. Start by creating (drilling) a hole at the unit's top. Venting enhances the performance of the fixtures and whisks sewer odors away from the breathable air in your home. 8 Common Upflush Toilet Problems And How To Fix Them? The dry vent goes up to the vent stack and the wet vent goes down to the main drain line for the room. Copyright Instead of using gravity to drain, an upflushing toilet has a heavy-duty pump activated by a float and switch. If your unit has a hole at the top, plug it with the clear plastic stopper that comes with it. Installing a Saniflo system isn't difficult! From the invention of the first macerator 60 years ago right up the innovation happening today, find out more in this section about Saniflo and its parent company; Group SFA. All rights reserved. The best way to vent a Saniflo system depends on where you installed the fixture. (Be sure to install it with the correct end upit is clearly marked.) 2. All of our products come with a plug power cord and requires 115 volts. The PVC pipe should stretch between the wall studs to the attic. Finally, attach the toilet to the pump (or extension pipe) by connecting the toilet to the smaller end of the gasket, and the pump to the larger, flexible side of the gasket. into a fine slurry, which it then mixes with flushing water. Finish the floor and walls and install the access panel. Ensure the system will be located no more than 12 feet below sewer level or 150 feet from the soil stack. Want to make your installation process even simpler? Once you locate the main drain system and the vertical vent stack, now it is time to find the wastewater drain connection located highest on the vent-and-soil stack. 1- The macerating/pump is connected to the spigot of a horizontal outlet toilet. When the lower portion of the tank fills, the pump turns on, forcing waste up through the 2-inch drain. Why install Macerator or Grinder pump? The Sanicompact 48 and Sanistar models do not require a vent connection since they are considered self contained units. After that, connect and tighten the two connectors. How Does an Upflush Toilet Work? Find an electric source complete with a GFI breaker to outfit your new system. You can start installing venting in the bathroom once you've got the framing walls in place. Any sink. Your pump comes with an 18 flex line so you can get out of the pump and head straight north without difficulty. For this type of setup, the use of a wye fitting and sanitary tee is very important. If the pumps experience any issues, please contact Saniflo technical support at the direct line (732)-305-2200 or the toll free number (800) 571-8191. Read this section before installation. If you want to hide the pipes, you can frame a lower ceiling to do so. DoItYourself.com, founded in 1995, is the leading independent How do you vent a Saniflo upflush toilet? - remodelormove.com Up Flush Toilet - YouTube Attach a garden hose to a water supply and run it into the flange hole. Ideally, install the fan between the shower and the toilet for proper air ventilation. A: The size of the discharge pipe on a Saniflo pump depends on the pump model. This can easily mess up the toilet. Toilets come with very simple mechanisms including a P-trap and a venting mechanism. Install the flooring and walls while being cautious not to damage the tank with lengthy fasteners. Upflush Toilet Venting | DoItYourself.com If everything is working correctly, youre all set! Ideally, it should not be higher than the uppermost floor with a kitchen sink or toilet. Locate the vent connection on the top of the upflush tank. Well also hammer out what makes a Saniflo toilet different, how you can choose the right one, and what you need to be mindful of during the installation. Saniflo Installation Instructions The Sanicubic 2 requires 220/240 volts and must be hard wired. You don't need to break up the floor! Equally, attach a horizontal line to reach the vent-and-soil stack. The final step in the installation process is to vent the system and attach the toilet. Cutting into the material of your soil stack, install a Y-connector to accommodate your macerators discharge pipe. Connect the toilet to a cold water supply line with a stop valve. Once youve installed the venting hose, its time to test the system. This is one of the easiest parts of the entire installation. Hand-tighten the water supply and voila! Questions of a Do It Yourself nature should be Just be sure youre positioning the supply line 10-12 from the floor and using cold, rather than hot, water. if you decide DIY way, then the first thing to do is to call a civil engineer and have him decide the best installation site for your basement bathroom toilet. Keep in mind that any fixtures you want to attach to your Saniflo system must also be on the same water level as the toilet. You can vent your Saniflo system anywhere, providing it meets the following requirements: air moves in and out and it adheres to local codes. The easiest way to find the vent pipe is to look for a PVC pipe sticking out of the ceiling. The discharge line cannot have any 90-degree angles. If you already have a sewer gas line in place, then connect the vent lines with the existing lines. The first step is to determine where youre going to vent the toilet. how did you end up venting it? One such place to install it is under the bathroom or kitchen sink. To achieve this, slice the stack with a hacksaw and put both extremities into the big fitting slots. Check out what Dan from Colorado did with these instructions and a new SaniAccess 3: All the installation manuals are posted on our website on the product description page. For an upflush venting unit, locate and disconnect the venting systems wall connection from the wall. to this site, and use it for non-commercial use subject to our terms of use. In general, you will want to avoid breaking through concrete walls or floors. Make sure the vent and drain conform to local plumbing codes. If you have prerequisite knowledge and skills in plumbing, you can try a DIY. Since wastes and liquids are heavier than gases, they usually occupy the lower sides of the pipes with the gases occupying the upper sides of the same pipes. and someone skilled in installing plumbing/venting. This water must go somewhere, and if there isnt enough venting, it can back up into your home and cause a flood. Install the toilet onto a wax ring where the bowl rests on the upflush unit. It is recommended to have an access panel either on the side or behind the wall in case the unit needs to be serviced. Movability. Also, make sure the rubber feet are installed on your unit before it is secured to the floor. All information is provided "AS IS." Alternatively, there could be a fault with the return valve. If it is convenient to tie the drain and vent lines for the upflush system into the main lines somewhere inside the building, this is usually the best approach. Upflush Toilet | Macerator Toilets & Toilet Pumps by Saniflo A: Sanicompact comes with a self-venting system, therefore, it doesnt require venting or connecting to a vent stack. I don't have access to any vent lines from the floor above and I was hoping to not have to run a new pipe all the way up to the roof from the basement. Your discharge pipes can be small between and 1, so you have some room to play with sizes and find one that works for you. This installation is done with a reducing wye whose sweep points downwards with the elbows being used to change the direction of the vent pipe as required. Here are a few additional Considerations for behind the wall (extension pipe) installations: Many installations allow for additional fixtures or appliances. But if you want to DIY, then we hope these steps we have mentioned above can come in handy. Urine is emptied from the bowl and into the main waste line by urethane-coated polypropylene. Just gather the following things before you begin: Your Saniflo Upflush Toilet. Vent pipes must be run in the standard manner . Gather all Your Equipment You won't need much to install your new system. The 4" pipe should cover 90% of the wall opening. However, such a reduction in the size of the vent pipe isnt permeated in areas covered by UPC jurisdiction. These vents exhaust methane and sewer gas up and away from the building's occupied spaces and allow the pressure in the drains to equalize. The vent should be located within 5 feet of the macerator, preferably close to the toilet. You should keep the venting hose away from your house to prevent unpleasant odors from entering your living area. In the event of a power loss, do not use the toilet or any sanitary fixture connected to the pump since it will not work until the power is restored. Fortunately, one alternative is available; an upflush toilet with a self-contained tank that allows water and waste from the toilet, sink, and shower. If you havent, its not hard to find one you love. You can also connect it to the sewer system in the basement or above the isolation in the attic. All fixtures connected to the Saniflo system must sit on the same level. In wet venting, the sink drained is connected to the toilet water line using a reducing sanitary tee. This post will teach you how to vent a basement bathroom and offer a simple diagram to get you started. While a Saniflo toilet looks and feels a lot like a standard toilet, they have a few important mechanical differences. Yes, it is necessary. How and where to install an air admittance valve. The only exception is the SaniBEST Pro. The next step in your install is to tap into a fresh water supply. A grinder pump is designed to handle the flush of human waste, toilet paper and sanitary napkins such as feminine hygiene products (Sanibest Pro, Sanigrind Pro, Sanicubic 1 and Sanicubic 2). You don't even need to be in close proximity to the main waste pipe (soil stack). Drainpipes for these fixtures must flow down to the upflush unit. Due to gravity, the seal closes by itself when the pressure inside the drain is equal to the atmospheric pressure outside the air admittance valve. The waste connection is made with a sanitary tee whose sweep is directed towards the sewer and then the vent pipe is glued to the port that would be facing upwards. The weight of the water forces its way past the P-trap and into the drain. Connect the System to Water Next, make it possible to flush your toilet by connecting the toilet tank to your water supply. The solution is in the use of Air Admittance Valves which are often called cheater vents since they perform the task of venting the toilet without the necessary structures found in normal plumbing vents. Use a flexible coupling to connect the outlet of your Saniflo system to the clean-out plug. With the vent pipe connected to the vent-and-soil stack, come down to your upflush unit and locate the vent connection. It incorporates a macerating system which can handle human waste and toilet paper in residential applications. "Reliable upflush toilet with hidden powerful macerating pump, and water-efficient dual flush system". The use of air admittance valves to vent toilets is a bit contentious and you should ensure its legal in your area before using one. The Sanicompact 48 and Sanistar models are dual flush systems and use 1 gallon (4 liters) and 1.28 gallons (4.8 liters) of water per flush. What I meant is that I would tie in to the horizontal drain line at a low point in the horizontal run, but I would still use a wye connection that is pointing up and waste falls down into the horizontal line. Upflush toilets like saniflo come with a pre-installed vent connection on the top of the tank. Quick Tips for Reducing Risk of Viral Infection in Public Bathrooms Upflush toilets are the way forward when it comes to home plumbing. Because Saniflo is the global leader of macerating upflush toilets, they manufacture them to work everywhere. While a wye fitting has a Y shape with a long and straight inlet port, the sanitary tee has a short curve on the inlet port. Remove the cap and attach it to the included 1 & 1/2-inch accordion connection. FAQs - Saniflo Enable registration in settings - general, How to Run Water Line to Fridge on Opposite Side of Sink. Its the best available, but sacrifices being quiet to do so. Saniaccess 2 | Saniflo Depot Installing a Bathroom in a basement is easy with Saniflo! Discharge Pipes. Ensure the room has proper ventilation to eliminate odors and moisture that could prove problematic later on. The best way to vent a toilet sink and shower is to use wet venting which is the method explained in the sections above. If youre not sure which model is right for you, were happy to help you choose. Plug the unit into a GFCI receptacle within reach of the access panel. If you need to run a vent line outside of the building, it has to terminate above the roof line. Start venting your basement bathroom once your bathroom framing walls are up. Macerating upflush toilets are the future of residential plumbing. If you find a leak, you will need to repair it immediately. Alternatively, you can install Saniflo as a wet system vent. One or two exhaust fans are good to ensure the bathrooms wet air is evacuated and the basement bathroom remains fresh and dry. Register today and take advantage of membership benefits. For typical usage, Saniflo macerators require descaling twice a year. The outlet of the tee should point upwards and be perpendicular to the drain pipe. Run the vent to the main stack. Youve probably already chosen the location where you want your unit to go. Re-read the instructions.. they clearly state in several spots NOT to tap into the bottom of an existing horizontal drain line.. You must have a vent on the tank. Several homeowners shy away from venting Saniflo upflush toilets in their basements because the task seems challenging. It has two sides, a stretchy side, and a stiff side. Connect the other end of the vent pipe to the city sewage system. This article will give you a sensible idea of how to vent a Saniflo Upflush toilet properly. You may freely link The recommended window ventilation is a minimum standard and may not be effective or reliable to offer proper ventilation for spaces in basements. Complementary products. Install the supply line. Some upflushing units, especially those installed in the '70s and '80s, were unreliable and needed frequent repairs. Install a backflow prevention valve on the discharge pipe. It must rest on a stable, fairly level surface. Better Homes & Gardens - 100 years of powering your passions at home. Saniflo SaniCOMPACT - Upflush Toilet I noticed recently that the toi How to Incorporate a Wall Mounted Coat Rack into Your Decor, Buying and Installing Bathroom Exhaust Fans, The Benefits of Building a Kitchen in Your Basement, 4 Most Common Locations for Sewer Gas Build Up. Install the subfloor and walls, being careful not to puncture the tank with any fasteners. 12 Everyday Items You Should Never Flush Down Your Toilet, Must-Know Plumbing Codes for a Successful Remodel, How to Install Plumbing Vent Lines in Your Bathroom, Our Plumbing Vent Diagrams & Tips Can Help You Plan Your Remodel, How to Install a Whirlpool Tub for a Luxurious Soaking Spot, How to Pick the Best Bathroom Layout for Your Dream Space, The Ultimate Guide to Bathroom Plumbing Diagrams and Layouts, The Ultimate Home Maintenance Checklist for Every Season, How to Frame an Interior Wall with Metal Studs, What to Know About Bathtubs, from Types to the Best Tub Materials, How to Run Pipes Through Walls and Floors for DIY Plumbing Work, How to Draw a Plumbing Plan for Your Next Remodeling Project. Flush the toilet and make sure that the waste is properly discharged. All of Saniflo products require an 1-1/2 inch vent pipe, which must be vented to the main vent stack as per plumbing codes. If you havent, its not hard to find one you love. Next, youll need to install the macerator. Insert the vent pipe into the hole, ensuring it is tight and secure. The vent must rise vertical from the sewage ejector containment until it reaches a point that is at least 6" high than the flood level rim of the highest fixture served by the ejector. JavaScript is disabled. There are many different ways to run the plumbing vent lines. Ideally, flush your Saniflo toilet at least once a day. . Keep in mind the SaniCompact and SaniStar do not require ventilation. There are essentially two types of venting options. Also, you cannot overload a vent stack. Connect the vent pipe from your upflush toilet to a point on the vent-and-soil stack upper than this drain connection. This toilet uses blades to grind up solids for easier pumping. Venting your toilet depends on various aspects including the size of the pipes, the design of the toilet and the regulations in your area. What is Rough in Height for Urinal Drain. The pump will not be able to move the water if there are any 90-degree angles in the discharge line. Insulate the pipes by wrapping them in foam pipe insulation. Test the system with a few quick flushes before use to ensure the waste gets appropriately discharged and that there are no leaks. Before sealing the unit, make sure the pump works. As per the regulations of the UPC, the ideal toilet vent distance is limited to 6 feet. Before you start the install, though, ensure youve got all your supplies in one place, and that the location is no more than 12 feet below the level of your sewer, or 150 feet from the nearest soil stack. Just like the normal toilet systems, you can poop or put any organic waste into your Saniflo toilet bowl and use its flushing mechanism to flush it down the drain. The use of mechanical vents, air admittance valves or similar devices are not permitted as these are considered one-way vent systems. Step 4 Attach a PVC collar fitting and then a PVC pipe, to the top of the tank's vent connection. This is certainly the 1-1/2-inch fitting on the upflush tank. Most importantly, ensure that the vent-and-soil stack is fixed at least 6 inches above, from the highest fixture as per the plumbing codes. In addition, this exercise curbs gurgling noises and helps keep your household safe from inhaling methane gas, which is hazardous to your health. To clarify, as long as your home meets the minimum requirements for airflow and the vent system is up to code, you should be all set. The sweep of the reducing sanitary tee should be towards the flow of the water and the outlet of the tee is to point upwards. This is probably a 1 1/2-inch fitting. Take these things into consideration as you finish the system: Ensure the Pipes are Freeze-Proof. This is best installed to a waste pipe which has a long-sweep elbow for the best results. Equally, read the plumbing codes of your local area since these codes vary from one area to the other. Macerating units have smaller discharge and drainpipes. If a new pump is to be purchased, it must be purchased from one of our distributors listed on our website (www.saniflo.com). To help the pump work as well as possible, limit bends and elbows in your discharge pipe. It is not recommended to use an air admittance valve or a mechanical spring-loaded device as they only allow air to flow one way. Once youve located the vent pipe, its time to attach the venting hose. Other materials that can clog your Saniflo toilet include sanitary pads and baby wipes. Be sure to configure the vent and drain in a code-approved manner. Saniflo Macerator Plumbing Installation Instructions - YouTube Ideally, any bends should be less than 45 degrees, and the pipe should be as straight as possible.